聯(lián) 系 人:段煜

電  話:15214379366

手  機(jī):16602115336

地  址:上海市崇明縣長興鎮(zhèn)潘園公路1800號(hào)2號(hào)樓9703室(上海泰和經(jīng)濟(jì)發(fā)展區(qū))

郵  編:201913

傳  真:021-80186165

郵  箱:435399850@qq.com

阿儀網(wǎng)商鋪:http://www.app17.com/c110001/

手機(jī)網(wǎng)站:m.jwswbio.com

資料下載

人肌營養(yǎng)不良蛋白(DMD)試劑盒(ELISA)

點(diǎn)擊次數(shù):697    發(fā)布時(shí)間:2017/7/14 15:22:06

· 上 傳 者: 上海極威生物科技有限公司

· 上傳時(shí)間:2017/7/14 15:22:06

· 文件大。31KB

· 文件類型:jpg

· 所屬分類:應(yīng)用方法

· 下載次數(shù):354次

· 查看次數(shù):697

· 資料簡介:  

 

Human DMD ELISA Kit

 

For the quantitative in vitro determination of Human Dystrophin concentrations in

 serum - plasma - celiac fluid - tissue homogenate - body fluid

 

 

 

 

 

 

 

 

FOR LABORATORY RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES. 

 

This package insert must be read in its entirety before using this product.

 

ELISA

ENZYME LINKED IMMUNOSORBENT ASSAY


INTENDED USE AND TEST PRINCIPLE

This DMD ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of DMD in the sample, this DMD ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus DMD concentration. The concentration of DMD in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4 before centrifugation for 20 minutes at approximately 2000×g. Remove serum and assay immediately or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1.  37 ℃ incubator

2.  Standard microplate reader capable of measuring absorbance at 450 nm

3.  Precision pipettes, disposable pipette tips and Absorbent paper

4.  Distilled or deionized water


REAGENTS PROVIDED 

All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

 

Name

96 determinations

48 determinations

MICROTITER PLATE

8*12strips

8*6strips

STANDARD6 vial

0.3ml/vial

0.3ml/vial

SAMPLE DILUENT

6.0ml

3.0ml

ENZYME CONJUGATE

10.0ml

5.0ml

WASH SOLUTION

25ml

15ml

SUBSTRATE A

6.0ml

3.0ml

SUBSTRATE B

6.0ml

3.0ml

STOP SOLUTION

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note:

1.  Standard concentration was followed by: 8, 4, 2, 1, 0.5, 0 ng/mL.

2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

 

PRECAUTIONS

1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.

2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.

3. Do not use kit components beyond their expiration date.

4. Use only deionized or distilled water to dilute reagents.

5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.

6. Use fresh disposable pipette tips for each transfer to avoid contamination.

7. Do not mix acid and sodium hypochlorite solutions.

8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.

9. All samples should be disposed of in a manner that will inactivate viruses.

10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.

11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.

12. Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.

13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

REAGENT PREPARATION AND STORAGE

Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

 

ASSAY PROCEDURE

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microtiter plate.

2.  Add 5l of Standard or Sample to the appropriate wells. Blank well doesnt add anyting.

3.  Add 10l of Enzymeconjugate to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4.  Wash the Microtiter Plate 4 times.

Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well completely with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.

5.  Add Substrate A 50μl and Substrate B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

6.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.

7.  Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

 

CALCULATION OF RESULTS

1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.

2. First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.

3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.

4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.

5. Intra-assay CV(%) is less than 10% and Inter-assay CV(%) is less than 15%.

6. Assay range: 0.25 ng/mL – 8 ng/mL.

7.  Sensitivity: The minimum detectable dose of Human DMD is typically less than 0.1 ng/mL.

8.  Cross-reactivity: This assay recognizes recombinant and natural Human DMD. No significant cross-reactivity or interference was observed.

9.  Storage: 2-8℃ (Use frequently); six months (-20℃)

10.  Standard curve

 

 

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!


人肌營養(yǎng)不良蛋白DMD試劑盒ELISA)

使用說明書

 

 

 

 

 

本試劑盒用于體外定量檢測(cè)血清、血漿、組織、細(xì)胞上清及相關(guān)液體樣本中人肌營養(yǎng)不良蛋白DMD)的含量。

有效期:6個(gè)月

保存條件:2-8℃

 

 

實(shí)驗(yàn)原理

試劑盒采用雙抗體一步夾心法酶聯(lián)免疫吸附試驗(yàn)(ELISA)。往預(yù)先包人肌營養(yǎng)不良蛋白DMD)捕獲抗體的包被微孔中,依次加入標(biāo)本、標(biāo)準(zhǔn)品、HRP標(biāo)記的檢測(cè)抗體,經(jīng)過溫育并徹底洗滌。用底物TMB顯色,TMB在過氧化物酶的催化下轉(zhuǎn)化成藍(lán)色,并在酸的作用下轉(zhuǎn)化成*終的黃色。顏色的深淺和樣品中的人肌營養(yǎng)不良蛋白DMD)呈正相關(guān)。用酶標(biāo)儀在450nm 波長下測(cè)定吸光度(OD 值),計(jì)算樣品濃度。

 

樣本處理及要求

1.  血清:全血標(biāo)本請(qǐng)于室溫放置2小時(shí)或4℃過夜后于1000g離心20分鐘,取上清即可檢測(cè),或?qū)?biāo)本放于-20℃-80℃保存,但應(yīng)避免反復(fù)凍融。
2.  血漿:可用EDTA或肝素作為抗凝劑,標(biāo)本采集后30分鐘內(nèi)于2 - 8°C 1000g離心20分鐘,或?qū)?biāo)本放于-20℃-80℃保存,但應(yīng)避免反復(fù)凍融。
3.  細(xì)胞培養(yǎng)物上清或其它生物標(biāo)本1000g離心20分鐘,取上清即可檢測(cè),或?qū)?biāo)本放于-20℃-80℃保存,但應(yīng)避免反復(fù)凍融。
注:標(biāo)本溶血會(huì)影響*后檢測(cè)結(jié)果,因此溶血標(biāo)本不宜進(jìn)行此項(xiàng)檢測(cè)。

需要而未提供的試劑和器材

1. 酶標(biāo)儀(450nm

2. 高精度加樣器及槍頭:0.5-10uL、2-20uL、20-200uL、200-1000uL

3. 37℃恒溫箱

4. 蒸餾水或去離子水

 

試劑盒組成

名稱

96孔配置

48孔配置

備注

微孔酶標(biāo)板

8×12

8×6

標(biāo)準(zhǔn)品

0.3mL*6

0.3mL*6

樣本稀釋液

6mL

3mL

檢測(cè)抗體-HRP

10mL

5mL

20×洗滌緩沖液

25mL

15mL

按說明書進(jìn)行稀釋

底物A

6mL

3mL

底物B

6mL

3mL

終止液

6mL

3mL

封板膜

2

2

說明書

1

1

自封袋

1個(gè)

1個(gè)

1.  標(biāo)準(zhǔn)品濃度依次為:8、42、10.5、0 ng/mL

2.  經(jīng)過大量正常標(biāo)本檢驗(yàn),標(biāo)本的正常濃度值均在試劑盒提供的檢測(cè)范圍內(nèi),實(shí)驗(yàn)過程中直接取50μL樣本上樣即可。當(dāng)有部分樣本值超過標(biāo)準(zhǔn)品濃度時(shí),可用樣本稀釋液將標(biāo)本進(jìn)行適當(dāng)稀釋后再進(jìn)行實(shí)驗(yàn)。

 

注意事項(xiàng)

1. 嚴(yán)格按照規(guī)定的時(shí)間和溫度進(jìn)行溫育以保證準(zhǔn)確結(jié)果。所有試劑都必須在使用前達(dá)到室溫20-25℃。使用后立即冷藏保存試劑。

2. 洗板不正確可以導(dǎo)致不準(zhǔn)確的結(jié)果。在加入底物前確保盡量吸干孔內(nèi)液體。溫育過程中不要讓微孔干燥掉。

3. 消除板底殘留的液體和手指印,否則影響OD值。

4. 底物顯色液應(yīng)呈無色或很淺的顏色,已經(jīng)變藍(lán)的底物液不能使用。

5. 避免試劑和標(biāo)本的交叉污染以免造成錯(cuò)誤結(jié)果。

6. 在儲(chǔ)存和溫育時(shí)避免強(qiáng)光直接照射。

7. 平衡至室溫后再打開密封袋以防水滴凝聚在冷板條上。

8. 任何反應(yīng)試劑不能接觸漂白溶劑或漂白溶劑所散發(fā)的強(qiáng)烈氣體。任何漂白成分都會(huì)破壞試劑盒中反應(yīng)試劑的生物活性。

9. 不能使用過期產(chǎn)品。

10. 如果可能傳播疾病,所有的樣品都應(yīng)管理好,按照規(guī)定的程序處理樣品和檢測(cè)裝置。

 

試劑準(zhǔn)備

試劑盒從冷藏環(huán)境中取出應(yīng)在室溫平衡后方可使用。

2洗滌緩沖液的稀釋:蒸餾水按120稀釋,即120×洗滌緩沖液加19份蒸餾水。

 

操作步驟

1.  從室溫平衡20min后的鋁箔袋中取出所需板條,剩余板條用自封袋密封放回4℃

2.  設(shè)置標(biāo)準(zhǔn)品孔和樣本孔,標(biāo)準(zhǔn)品孔各加不同濃度的標(biāo)準(zhǔn)品50μL;

3.  樣本孔待測(cè)樣本50μL;空白孔不加。

4.  除空白孔外,標(biāo)準(zhǔn)品孔和樣本孔中每孔加入辣根過氧化物酶(HRP)標(biāo)記的檢測(cè)抗體100μL,用封板膜封住反應(yīng)孔,37℃水浴鍋或恒溫箱溫育60min。

5.  棄去液體,吸水紙上拍干,每孔加滿洗滌液350μL,靜置1min,甩去洗滌液,吸水紙上拍干,如此重復(fù)洗板5次(也可用洗板機(jī)洗板)。

6.  每孔加入底物A、B50μL,37℃避光孵育15min。

7.  每孔加入終止液50μL,15min內(nèi),在450nm波長處測(cè)定各孔的OD值。

 

實(shí)驗(yàn)結(jié)果計(jì)算

所測(cè)標(biāo)準(zhǔn)品的OD為橫坐標(biāo),標(biāo)準(zhǔn)品的濃度值為縱坐標(biāo),在坐標(biāo)紙上或用相關(guān)軟件繪制標(biāo)準(zhǔn)曲線,并得到直線回歸方程,將樣品的OD值代入方程,計(jì)算出樣品濃度

 

試劑盒性能

1.  檢測(cè)范圍0.25 ng/mL  8 ng/mL。

2.  靈敏度:檢測(cè)濃度小于0.1 ng/mL

3.  特異性:不與其它可溶性結(jié)構(gòu)類似物交叉反應(yīng)。

4.  重復(fù)性:板內(nèi)變異系數(shù)小于10% ,板間變異系數(shù)小于15% 

首 頁| 公司介紹| 產(chǎn)品展示| 公司新聞| 榮譽(yù)證書| 資料下載| 技術(shù)文章| 聯(lián)系我們| 客戶留言

阿儀網(wǎng) 設(shè)計(jì)制作,未經(jīng)允許翻錄必究.   聯(lián)系人:段煜 聯(lián)系電話:15214379366 ICP備案號(hào):滬ICP備15046135號(hào)-2 總訪問量:4113289 管理登錄

主營產(chǎn)品:ELISA試劑盒,標(biāo)準(zhǔn)品,細(xì)胞株,抗體,生物試劑,化學(xué)試劑,培養(yǎng)基,血清,實(shí)驗(yàn)耗材,ABcam抗體,CST抗體,Santa抗體,ATCC細(xì)胞株,人elisa檢測(cè)試劑盒,小鼠elisa試劑盒,大鼠elisa試劑盒,牛elisa試劑盒,羊elisa試劑盒,豬elisa試劑盒,犬elisa試劑盒,植植物elisa試劑盒,elisa 檢測(cè)試劑盒報(bào)價(jià),試劑盒批發(fā),免費(fèi)代測(cè)elisa 試劑盒,細(xì)胞株供應(yīng)商,實(shí)驗(yàn)外包

掃一掃,關(guān)注我們

9

阿儀網(wǎng)推薦收藏該企業(yè)網(wǎng)站

客戶服務(wù)熱線:

15214379366

16602115336

工作時(shí)間

8:30-18:30